ZUDC - UDA & RA80 drive diagnostic HARDWARE REQUIREMENTS: PDP-11 computer with 28K memory KW11-L or KW11-P, UDA50 with RA80's. OPERATING PROCEDURES: run ZUDCA0 - DS>START/FLA:PNT - HARDWARE CHANGES? if Y, program ask for: #UNITS? number of units to be tested ADDRESS?(172150) VECTOR?(154) BR LEVEL?(5) UNIBUS BURST RATE?(0 to 64) DRIVE NUM?(plug number) EXERCISE CUSTOMER DATA? if Y, customer data will be destoyed! Otherwise test will run on field engineer tracks only. - SOFTWARE CHANGES?NO Program will start and print test # Test 1: UDA50 test Test 2: InternalRA80 microtests Test 3: Functional test Test 4: Performance test SWITCH SETTINGS: HOE halt on error LOE loop on error IER inhibit all error reports IBR inhibit all error except first level IXR inhibit extended report PRI print messages on line printer PNT print test number BOE bell on error ISR inhibit statistics report IDR inhibit drive dropping LOT loop on test RUN TIME: 2 minutes. NOTES: Customer data will not be destroyed unless you ask for it. ZUDE - RA80 formatter HARDWARE REQUIREMENTS: PDP-11 computer with 28K memory UDA50 with RA80's. OPERATING PROCEDURES: run ZUDEA0 - DS>START/PASS:1 - HARDWARE CHANGES? Y program will ask for: #UNITS? number of units to be formatted ADDRESS?(172150) DRIVE NUM?(plug number) USE RESIDENT FCT? NO DOWN LINE LOAD FCT? NO SERIAL NUMBER TO BE ASSIGNED? WORD 1? WORD 2? (HDA serial numb.) WORD 3? WORD 4? - SOFTWARE CHANGES?NO SWITCH SETTINGS: HOE halt on error LOE loop on error IER inhibit all error reports IBR inhibit all error except first level IXR inhibit extended report PRI print messages on line printer PNT print test number BOE bell on error ISR inhibit statistics report IDR inhibit drive dropping LOT loop on test RUN TIME: 1/2 hour. NOTES: It is mandatory to specify 1 pass only when starting the test !!! DS>START/PASS:1