ZTUI - TU45/TM02 Data Reliability test ABSTRACT: This program will test all tape drive functions such as writing, reading, rewinding, tape positioning, EOT-BOT sensing and assumes a good RH and TM02. This program has no fixed parameters. HARDWARE REQUIREMENTS: PDP-11 with 8KW of memory, TM02 controller and 1-8 TU45 OPERATING PROCEDURES: Start/restart addresses: 200 initial start, all parameters 204 restart, last pattern used 210 restart, original pattern 240 auto-sequence 300 restart, short parameter list - load and start program at 200 - set desired switches - answer the questions: REGISTER START: 172440 VECTOR ADDRESS: 224 DRIVE NUMBER: (0-7) SLAVE NUMBER: (0-7) DENSITY: (0-4)3=800BPI, 4=1600 BPI PARITY: (0 or 1) 0=ODD 1=EVEN FORMAT: (14 or 15)14=NORMAL 15=CORE DUMP SLAVE NUMBER: (0-7) IF NO MORE JUST CR RECORD COUNT: 100 (1-177777) CHARACTER COUNT: 200 (20-4000) PATTERN NUMBER: 1 (0-15) TAPE MARK=0 (0 or 1) SINGLE PASS=0 (0 or 1) ENTER STALLS - READ=1 } - WRITE=1 } (1-177777) EACH INCREMENT is 2.6 µSec - TURN AROUND=1 } SWITCH SETTINGS: SW 15 =1 halt on error SW 14 =1 print statistics SW 13 =1 dont check data errors SW 12 =1 dont check write status SW 11 =1 dont check read status SW 10 =1 dont print errors SW 09 =1 rewind all tapes SW 08 =1 random data SW 07 =1 random character count SW 06 =1 random record count SW 05 =1 yozzle current record SW 04 =1 do retries SW 03 =1 dont read forward SW 02 =1 dont read reverse SW 01 =1 read forward first SW 00 =1 dont write NOTES: Recommended switch settings SW4,6,7,8 to randomize test and get information about bad spots. ZTUJ - TU45/TM02 Basic Function test ABSTRACT: This program will test all of the basic operations of the TU45/TM02 mag tape system. All functions: read, write, space, erase, rewind, etc. will be tested and as far as possible some of the RH11 functions. HARDWARE REQUIREMENTS: PDP-11 with 8KW of memory, TM02 controller and one TU45. OPERATING PROCEDURES: Start/restart addresses: 200 start 210 restart - tape unit must be loaded at BOT and on-line - load and start program at 200 - set desired switches - answer the questions: REGISTER START: 172440 VECTOR ADDRESS: 224 DRIVE NUMBER: (0-7) SLAVE NUMBER: (0-7) RH11 OR RH70: (RH11=0, RH70=1) RH ONLY: (0 or 1) NRZ ONLY: (0 or 1) SWITCH SETTINGS: SW 15 =1 halt on error SW 14 =1 loop on error SW 13 =1 dont print errors SW 12 =1 inhibit iterations SW 11 =1 continuous cycle SW 10 =1 halt after current test SW 04-00 select test # (1-24) 0=ALL ZTUK - TU45/TM02 Control Logic test ABSTRACT: This program will test all control logic (test 1-41 and 57-64) and data formatting (test 42-56) within the TM02 formatter. This program has no fixed parameters. HARDWARE REQUIREMENTS: PDP-11 with 8KW of memory, TM02 controller and one TU45. OPERATING PROCEDURES: Start/restart addresses : 200 start 210 restart - tape unit must be loaded at BOT and on-line - load and start program at 200 - set desired switches - answer the questions: REGISTER START: 172440 VECTOR ADDRESS: 224 DRIVE NUMBER: (0-7) DRIVE NUMBER: (0-7) if no more just CR SLAVE NUMBER: (0-7) SLAVE NUMBER: (0-7) if no more just CR NRZ ONLY: (0 or 1) STATIC TEST ONLY (0 or 1) SWITCH SETTINGS: SW 15 =1 halt on error SW 14 =1 loop on error SW 13 =1 dont print errors SW 12 =1 inhibit iterations SW 11 =1 continuous cycle SW 10 =1 halt after current test SW 09 =1 manual intervention test SW 08 =1 inhibit wrap data checks SW 07 =1 inhibit wrap status checks SW 06 =1 selectable wrap data pattern (single test) SW 05 =1 select test # (1-64) 0=ALL RUN TIME : With iterations approx 3 min., without approx 30 sec. ZTUL - TU45/TM02 Drive Function Timer ABSTRACT: This program will check both the logic generated time delays and the distances travelled by the tape in response. Actual tape speed may also be checked by using the speed tests with an 800 BPI skew tape. HARDWARE REQUIREMENTS: PDP-11 with 4KW of memory, TM02 controller and 1-8 TU45. OPERATING PROCEDURES: Start/restart address : 200 - load and start program at 200 - set desired switches - answer the questions: TYPE FIRST ADDRESS CONTROLLER: 172440 TYPE TM02 DRIVE #'S TO BE TESTED: 0 (0-7) FOR TM02 DRIVE0-TYPE SLAVE #'S TO BE TESTED: 0 (0-7) TAPE SPEED TESTS ONLY: (YES/NO=1/0) 0 NRZ ONLY: (YES/NO= 1/0) - THE PROGRAM WILL BEGIN TIMING FUNCTIONS. - ON COMPLETION THE PROCESSOR WILL HALT. - TO REPEAT TEST, PRESS CONTINUE. SWITCH SETTINGS: SW 15 =1 halt on error SW 14 =1 loop current test SW 13 =1 inhibit error printout SW 11 =1 inhibit iterations SW 10 =1 dont print function times SW 09 =1 bell on error SW 07 =1 halt after selected test SW 06 =1 continuous cycle SW 05-00 select test # (1-32) 0=ALL NOTES: If speed tests are selected a master skew tape must be used.