ZRML - RM05/03/02 disk formatter ABSTRACT: - format pack - verify header and data (read) - check header and data field (format and writes different patters three times) HARDWARE REQUIREMENTS: PDP-11 computer with 16 K memory, KY11-L or KY11-P, RH11 or RH70, one to eight drives. SOFTWARE: The following maindecs should be run successfully before: RM05/03/02 diskless controller tests #1 and #2, RM05/03/02 functional controller tests #1, #2, and #3. OPERATING PROCEDURES: 200 start program 204 input parameters - load program, start 200 - PROGRAM MODE (F, C or V) - answer other questions SWITCH SETTINGS: SW15 - Halt program on error SW13 - Inhibit error print-out SW10 - Bell on error SW9 - Loop on error SW2 - Don't display system status after initial start SW1 - Loop on the current track SW0 - Loop the program on the selected drive ZRMM - RM05/03/02 subsystem functional test part #1 ABSTRACT: - establish confidence in drive basic operation - establish confidence in the drive/adaptor electrical interface - verify subsystem functionality HARDWARE REQUIREMENTS: PDP-11 computer with 16 K memory, KY11-L or KY11-P, RH11 or RH70, one to eight drives. SOFTWARE: The following maindecs should be run successfully before: RM05/03/02 diskless diagnostic part #1 and #2. OPERATING PROCEDURES: 200 start program - load program, start 200 SWITCH SETTINGS: SW15 - Halt program on error SW14 - Loop on test SW13 - Inhibit error print-out SW11 - Inhibit iterations SW10 - Bell on error SW9 - Loop on error SW8 - Loop on test as per 0-7 ZRMN - RM05/03/02 subsystem functional test part #2 ABSTRACT: - establish confidence in drive basic operation - establish confidence in the drive/adaptor electrical interface - verify subsystem functionality HARDWARE REQUIREMENTS: PDP-11 computer with 16 K memory, KY11-L or KY11-P, RH11 or RH70, one to eight drives. SOFTWARE: The following maindecs should be run successfully before: RM05/03/02 diskless diagnostic part #1 and #2, RM05/03/02 functional test part #1. OPERATING PROCEDURES: 200 start program - load program, start 200 SWITCH SETTINGS: SW15 - Halt program on error SW14 - Loop on test SW13 - Inhibit error print-out SW11 - Inhibit iterations SW10 - Bell on error SW9 - Loop on error SW8 - Loop on test as per 0-7 ZRMO - RM05/03/02 subsystem functional test part #3 ABSTRACT: - establish confidence in drive basic operation - establish confidence in the drive/adaptor electrical interface - verify subsystem functionality HARDWARE REQUIREMENTS: PDP-11 computer with 16 K memory, KY11-L or KY11-P, RH11 or RH70, one to eight drives. SOFTWARE: The following maindecs should be run successfully before: RM05/03/02 diskless diagnostic part #1 and #2, RM05/03/02 functional test part #1 and #2. OPERATING PROCEDURES: 200 start program - load program, start 200 SWITCH SETTINGS: SW15 - Halt program on error SW14 - Loop on test SW13 - Inhibit error print-out SW11 - Inhibit iterations SW10 - Bell on error SW9 - Loop on error SW8 - Loop on test as per 0-7 ZRMP - RM05/03/02 diskless controller diagnostic part #1 ABSTRACT: - detect RH massbus controller faults - detect RM massbus adaptor failures - resolve it by giving the FRU HARDWARE REQUIREMENTS: PDP-11 computer with 16 K memory, KY11-L or KY11-P, RH11 or RH70, one to eight drives. SOFTWARE: No maindecs have to be be run. OPERATING PROCEDURES: 200 start program - load program, start 200 SWITCH SETTINGS: SW15 - Halt program on error SW14 - Loop on test SW13 - Inhibit error print-out SW11 - Inhibit iterations SW10 - Bell on error SW9 - Loop on error SW8 - Loop on test as per 0-7 ZRMQ - RM05/03/02 diskless controller diagnostic part #2 ABSTRACT: - detect RM massbus adaptor failures - resolve it by giving the FRU HARDWARE REQUIREMENTS: PDP-11 computer with 16 K memory, KY11-L or KY11-P, RH11 or RH70, one to eight drives. SOFTWARE: The following maindecs should be run successfully before: RM05/03/02 diskless controller tests #1 OPERATING PROCEDURES: 200 start program - load program, start 200 SWITCH SETTINGS: SW15 - Halt program on error SW14 - Loop on test SW13 - Inhibit error print-out SW11 - Inhibit iterations SW10 - Bell on error SW9 - Loop on error SW8 - Loop on test as per 0-7 ZRMR - RM05/03/02 dual port test part #1 ABSTRACT: - tests dual port logic - doesn't test data handling in dual port mode - both ports are cabled to same massbus by means of special adaptor cable HARDWARE REQUIREMENTS: PDP-11 computer with 16 K memory, KY11-L or KY11-P, RH11 or RH70, one drive, RM dual port test cable. SOFTWARE: The following maindecs should be run successfully before: RM05/03/02 diskless controller tests #1 and #2 RM05/03/02 functional controller tests #1, #2, and #3 OPERATING PROCEDURES: 200 start program 204 restart program 210 input parameters - connect dual port test cable - load program - set the port select switch to A/B - start 200 - type drive number SWITCH SETTINGS: SW15 - Halt program on error SW14 - Loop on test SW13 - Inhibit error print-out SW11 - Inhibit iterations SW10 - Bell on error SW9 - Loop on error RUNTIME: 45 seconds for first pass, 2,5 minutes after ZRMS - RM05/03/02 dual port test part #2 ABSTRACT: - tests dual port logic - doesn't test data handling in dual port mode - both ports are cabled to same massbus by means of special adaptor cable HARDWARE REQUIREMENTS: PDP-11 computer with 16 K memory, KY11-L or KY11-P, RH11 or RH70, one drive, RM dual port test cable. SOFTWARE: The following maindecs should be run successfully before: RM05/03/02 diskless controller tests #1 and #2 RM05/03/02 functional controller tests #1, #2, and #3 RM05/03/02 dual port test #1 OPERATING PROCEDURES: 200 start program 204 restart program 210 input parameters - connect dual port test cable - load program - set the port select switch to A/B - start 200 - type drive number SWITCH SETTINGS: SW15 - Halt program on error SW14 - Loop on test SW13 - Inhibit error print-out SW11 - Inhibit iterations SW10 - Bell on error SW9 - Loop on error RUNTIME: 1 minute per pass ZRMT - RM05/03/02 compatibility test ABSTRACT: - verifies the compatibility of up to 16 drives HARDWARE REQUIREMENTS: PDP-11 computer with 16 K memory, KY11-L or KY11-P, RH11 or RH70, one to eight drives per controller. SOFTWARE: The following maindecs should be run successfully before: RM05/03/02 diskless controller tests #1 and #2 RM05/03/02 functional controller tests #1, #2, and #3 Pack must be formatted OPERATING PROCEDURES: 200 start program 204 pass 1 on all controllers and input parameters 210 pass 2 on all controllers and input parameters - load program - load a formatted pack in drive to be tested - start 200 - DRIVES = 0,1,2 SWITCH SETTINGS: SW15 - Halt program on error SW14 - Loop on test SW13 - Inhibit error print-out SW12 - Report description only, no errors SW10 - Bell on error SW9 - Loop on error SW8 - Apply random stall between operations SW7 - Type bad sector file at start RUNTIME: 2 minutes per RM03, 5 minutes per RM05 ZRMU - RM05/03/02 performance exerciser ABSTRACT: - interactive tests - multidisk - supports dual port HARDWARE REQUIREMENTS: PDP-11 computer with 16 K memory, KY11-L or KY11-P, RH11 or RH70, one to eight drives. SOFTWARE: The following maindecs should be run successfully before: RM05/03/02 diskless controller tests #1 and #2 RM05/03/02 functional controller tests #1, #2, and #3 OPERATING PROCEDURES: 200 start program 204 input parameters - load program - load a formatted pack in drive to be tested - start 200 - choice one sector size for heavy mode seek SWITCH SETTINGS: SW15 - Halt program on error SW13 - Inhibit error print-out SW10 - Bell on error SW7 - Display all data compare errors SW6 - Do not alter the current operation parameters SW5 - Partial register display if error SW4 - Inhibit maximum error count check SW3 - Display sector in error SW2 - Inhibit subsystem status report during startup SW1 - Inhibit data compare after read SW0 - Read only mode KEYBOARD COMMAND: TN test drive "N" DN drop drive "N" SN statistics of drive "N" WN write pattern on drive "N" RN sequential read on drive "N" WTN write pattern + test on drive "N" RUNTIME: depends on chosen parameters ZRMV - RM05/03/02 extended drive test ABSTRACT: - verifies that the drive can perform seeks - verifies the access times - verifies the track and sector addressing circuits - verifies data storage and retrieval HARDWARE REQUIREMENTS: PDP-11 computer with 16 K memory, KY11-L or KY11-P, RH11 or RH70, one to eight drives. SOFTWARE: The following maindecs should be run successfully before: RM05/03/02 diskless controller tests #1 and #2 RM05/03/02 functional controller tests #1, #2, and #3 OPERATING PROCEDURES: 200 start program 204 input parameters 210 select RH11,RH70 addresses 214 combines 204 and 210 - load program - load a formatted pack in drive to be tested - start 200 - typing 'control C' enters conversation mode SWITCH SETTINGS: SW15 - Halt program on error SW14 - Loop on test SW13 - Inhibit error print-out SW12 - Type-out test number SW11 - Inhibit iteration SW10 - Bell on error SW9 - Loop on error SW8 - Print error messages on line printer SW7 - Read 'C.SWR' settings from TTY SW6 - Inhibit time reports SW5 - Report one error per sector SW4 - Inhibit writes in test 20 SW3 - Inhibit writechecks in test 20 SW2 - Inhibit read and software compare in test 20 SW1 - Inhibit software compare in test 20 SW0 - Perform read after write check error in test 20 RUNTIME: 15 minutes for one RM03, 16,5 minutes for one RM05