ZLPK - LP05/14/11 line printer test ABSTRACT: This program verifies proper operation of the LP05, LP14 line printer and its associated M7258 control unit. HARDWARE REQUIREMENTS: PDP-11 CPU, 8 KW memory, console terminal. SOFTWARE: Error tags will be listed as ''ERRXX'' where XX is error number Additional information may be obtained from the listing. OPERATING PROCEDURES: Starting address: 200 initial starting address 600 to skip manual intervation. SWITCH SETTINGS: SW 15 =1 loop on error (in test 1 only) SW 14 =1 optional DAVFU available SW 13 =1 (up) 96 character set =0 (down) 64 character set SW 12 =1 loop on test SW 11 =1 send only one character to line printer in scope driver - then halt SW 10 =1 (up) LP14 =0 (down) LP05/LP11 SW 09 =1 inhibit error reports SW 00 =1 used for print speed manual timing if no KW11-L or KW11-P available RUN TIME: 1 pass takes approximately 5 min. NOTES: Individual tests and their starting address: 200 normal start address (with manual intervention) 400 print speed test using manual timing 404 print speed test using KW11-L 410 print speed test using KW11-P 414 check top of form switch settings 600 interface and data path test (general print test) 700 scope driver routine 720 scope driver routine without line feed For further information refer to the listing. *** LP06 can also be tested with this test ***