EKBA - 11/70 CPU basic instruction ABSTRACT: This program is the first part of the 11/70 instruction test; it will check out the basic instructions. HARDWARE REQUIREMENTS: PDP 11/70 CPU, Operators Console, LA36 or equivalent terminal, 16 KW memory. OPERATING PROCEDURES: LOAD ADDRESS 200 START SWITCH SETTINGS: None. RUN TIME: First pass - 5 seconds Subsequent pass - 2 minutes NOTES: Run both CPU - instructions diagnostics (CEKBA and CEKBB) to fully test the 11/70 instructions. EKBB - 11/70 CPU advanced instruction ABSTRACT: This program is the second part of the 11/70 instructions test; it will test advanced instructions and miscellaneous logic. HARDWARE REQUIREMENTS: PDP 11/70 CPU with Operators Console, LA36 or equivalent terminal, 32 KW memory. OPERATING PROCEDURES: LOAD ADDRESS 200 START SWITCH SETTINGS: SW 15=1 or up halt on error SW 14=1 or up loop on test SW 13=1 or up inhibit error typeouts SW 12=1 or up inhibit T-bit trapping SW 11=1 or up inhibit iterations SW 10=1 or up ring bell on error SW 09=1 or up loop on error SW 08=1 or up loop on test in SW <07:00> SW 07=1 or up no action SW 06=1 or up skip bus request 6 test SW 05=1 or up skip bus request 5 test SW 04=1 or up skip bus request 4 test SW 00=1 or up skip operator intervention tests RUN TIME: First pass - 8 seconds Subsequent pass - 3 minutes SOFTWARE: This program will run: - as stand alone NOTES: If BR5 test are to be run ensure that a BR5 device is on the system (i.e. RH70, RK , RS , RP or TM). See also notes on CEKBA ! EKBC - 11/70 cache test 1 ABSTRACT: This program is the first part of the 11/70 cache tests; it will basically test CCB - and CDP - cache modules. HARDWARE REQUIREMENTS: PDP 11/70 CPU with cache, LA36 or equivalent terminal, 28 KW memory. OPERATING PROCEDURES: LOAD ADDRESS 200 START SWITCH SETTINGS: SW 15=1 or up halt on error SW 14=1 or up loop on test SW 13=1 or up inhibit error typeouts SW 12=1 or up no action SW 11=1 or up inhibit iterations SW 10=1 or up ring bell on error SW 09=1 or up loop on error SW 08=1 or up loop on test in SW <06:00> SW 07=1 or up skip execution of tests which use memory management SW 06-00 test number to loop on RUN TIME: First pass - 10 seconds Subsequent pass - 2 minutes SOFTWARE: This program will run: - as stand alone NOTES: These programs assume that the CPU is functional. Run both 11/70-cache diagnostics (CEKBC and CEKBD) to fully test proper cache operation. EKBD - 11/70 cache test 2 ABSTRACT: This program is the second part of the 11/70 cache tests; it will basically test ADM - and DTM - cache modules. HARDWARE REQUIREMENTS: PDP 11/70 CPU with cache, LA36 or equivalent terminal, 28 KW memory. OPERATING PROCEDURES: LOAD ADDRESS 200 START SWITCH SETTINGS: SW 15=1 or up halt on error SW 14=1 or up loop on test SW 13=1 or up inhibit error typeouts SW 12=1 or up no action SW 11=1 or up inhibit iterations SW 10=1 or up ring bell on error SW 09=1 or up loop on error SW 08=1 or up loop on test in SW <06:00> SW 07=1 or up skip execution of test which use memory management SW 06-00 test number for looping RUN TIME: First pass - 10 seconds Subsequent pass - 2 minutes SOFTWARE: This program will run: - as stand alone NOTES: See notes on CEKBC-test description! EKBE - 11/70 memory management ABSTRACT: This program will test all of the 11/70 memory - management logic. HARDWARE REQUIREMENTS: PDP 11/70 CPU with cache and memory - management, LA36 or equivalent terminal, 20 KW memory. OPERATING PROCEDURES: LOAD ADDRESS 200 START SWITCH SETTINGS: SW 15=1 or up halt on error SW 14=1 or up loop on test SW 13=1 or up inhibit error type outs SW 12=1 or up inhibit Trace trap on every other pass SW 11=1 or up inhibit iterations SW 10=1 or up ring bell on error SW 09=1 or up loop on error SW 08=1 or up loop on test in SW <06:00> SW 07=1 or up inhibit multiple error type outs SW 06-00 test number to loop on For special starting addresses, see listing: 4.1 Starting addresses RUN TIME: First pass - 10 seconds Subsequent pass - 2 minutes SOFTWARE: This program will run: - as stand alone NOTES: If it appears that cache is causing some trouble, it is possible to disable cache. See listing : 4.3 Special starting procedure. EKBF - 11/70 UNIBUS map ABSTRACT: This program will test the 11/70 UNIBUS map logic. HARDWARE REQUIREMENTS: PDP 11/70 CPU with cache, memory management, LA36 or equivalent terminal, 8 KW memory. OPERATING PROCEDURES: LOAD ADDRESS 200 START SWITCH SETTINGS: SW 15=1 or up halt on error SW 14=1 or up loop on test SW 13=1 or up inhibit error type outs SW 12=1 or up inhibit Trace trap SW 11=1 or up inhibit iterations SW 10=1 or up ring bell on error SW 09=1 or up loop on error SW 08=1 or up loop on test in SW <06:00> SW 07=1 or up inhibit multiple error type outs SW 06-00 test number to loop on For special starting addresses, see listing: 4.1 Starting addresses RUN TIME: First pass - 10 seconds Subsequent pass - 2 minutes SOFTWARE: This program will run: - as stand alone NOTES: The CPU, cache and memory management diagnostics should be run before this program. If it appears that cache is causing some trouble, it is possible to disable cache. See listing : 4.3 Special starting procedure. EMKA - main memory test ABSTRACT: This program will functionally test and verify all 11/70 main memory. MK11, MJ11 and mixed systems are tested. HARDWARE REQUIREMENTS: PDP 11/70 CPU with LA36 or equivalent terminal, 64 KW memory. OPERATING PROCEDURES: LOAD ADDRESS 200 START SWITCH SETTINGS : SW 00=1 or up detect single bit errors For the rest of the switches, see MK11 memory maintenance card! To stop the program: - set SW 08=1, or - type Control-C RUN TIME: Execution time depends on amount and type of memory under test. SOFTWARE: This program will run: - as stand alone - under ACT-11 monitor NOTES: For function of field service mode ( FSM ) commands, see MK11 memory maintenance card, p. 16. EQKC - instruction exerciser ABSTRACT: This program is a comprehensive check of the 11/70 CPU cluster. It executes each instruction in all adrs. modes, test traps, interrupts, mapping box, mem. management, memory, UNIBUS and MASSBUS. HARDWARE REQUIREMENTS: PDP 11/70 CPU with cache, memory management, line clock, LA36 or equivalent terminal, 16 KW memory. Optional: FP11-B or FP11-C, RP03, RK05, RP04, UNIBUS exerciser, MASSBUS tester. OPERATING PROCEDURES: LOAD ADDRESS 200 START SWITCH SETTINGS: SW 15=1 or up halt on error SW 14=1 or up loop on test SW 13=1 or up inhibit error type outs SW 12=1 or up inhibit UNIBUS exerciser SW 11=1 or up inhibit subtest iterations SW 10=1 or up ring bell on error SW 09=1 or up loop on error SW 08=1 or up relocate with disk SW 07=1 or up inhibit system size typeout SW 06=1 or up inhibit relocation SW 05=1 or up inhibit round robin SW 04=1 or up inhibit random disk address SW 03=1 or up inhibit MASSBUS tester SW 02-00 specific device code used with SW05 RUN TIME: Execution time is dependent on the amount of memory. i.e. 32 KW memory : - 3 minutes 128 KW memory : - 9 minutes The program supports Control-C. SOFTWARE: This program will run: - as stand alone - under ACT-11 monitor NOTES: Allthough this program is a test of the 11/70 CPU cluster, it is advisable that all CPU, cache, memory management and UNIBUS map diagnostics run first.